  "case": "0095 tension only",
  "force_N": 610.0,
  "load_factor": 0.1,
  "original_geometry_constraints_and_constitutive_preserved": true,
  "difference": "Residual/tangent quadrature degree2 vs6; exact same4 physical GP locations used for saved stress comparison",
  "U_relative_L2_all": 0.00011779494273293877,
  "U_relative_L2_selected100": 0.00013115522617750306,
  "VM_GP_relative_L2_all": 0.027804224384275624,
  "current_rule_label_relative_L2_selected100": 0.005809703748678841,
  "pair": [
    {
      "node": 6956,
      "original4_GPmax_volume_label_MPa": 7.731516479036327,
      "degree6_GPmax_volume_label_MPa": 7.738108683436119
    },
    {
      "node": 6954,
      "original4_GPmax_volume_label_MPa": 13.25181953462068,
      "degree6_GPmax_volume_label_MPa": 13.381858484113186
    }
  ],
  "interpretation": "A bounded quadrature sensitivity check at10% load, not a full6100N corrected solution, mesh convergence certificate, or replacement training labels."
}